Distributed Controller

Distributed Controller

MOQ : 1 Piece

Business Type Manufacturer, Exporter, Supplier, Retailer, Wholesaler

Preferred Buyer From

Location Worldwide

SIMATIC ET 200SP : High Performance in a very compact design SIMATIC ET200SP Enlarge SIMATIC ET 200SP CPUs with PROFINET feature the same functionalities as the CPU 1511 / CPU 1513 of the S7-1500 controller system, e.g. integrated trace function, integrated system diagnostics, integrated security, web server and fully symbolic programming. These CPUs come with three integrated Ethernet ports, two Ethernet connection ports can be flexibly selected by means of bus adapters as a cost saving feature. The CPUs can also be configured as interface modules with the I Device functionality. As advantages can be mentioned an interference-resistant configuration due to short signal and encoder wiring and reduced wiring requirements. The CPUs supports the additional functions as PROFIenergy, Isochronous mode, configuration control and DP master.

 

SIMATIC ET 200SP open controller: The SIMATIC ET 200SP Open Controller is the first controller of this type to combine the functions of a PC-based software controller with visualization, PC applications and central I/Os in a compact device. The already installed and preconfigured SIMATIC S7-1500 Software Controller, the PC-based version of SIMATIC S7-1500, is used for control. This controller is operated independently of Windows and thus ensures high system availability. This facilitates the controller's rapid start-up, supports Windows updates, and reboot during ongoing operation. Even a failure of Windows does not have any impact on the controller.

 

SIMATIC ET 200pro: The ET 200pro distributed I/O system is being expanded with CPU 1516pro-2 PN and CPU 1516pro F-2 PN. The new CPUs are based on the S7-1500 CPU 1516-3 PN/DP and offer two PROFINET IO communication interfaces. The CPUs 1516pro-2 PN Standard and Fail-safe have a PROFINET IO interface with three PROFINET ports. The three ports have the same properties. In addition, you can implement a ring redundancy (MRP or MRPD) with ports 1 and 2. Ports 1 and 2 with M12 cable gland, as known from the IM154-8 PN/DP CPUs, are connected to the CPU by means of a connection module. Port 3 is a RJ45 socket that is permanently integrated into the CPU enclosure behind a porthole. The 1516pro-2 PN and 1516pro F-2 PN CPUs support PROFINET IRT through this PN interface and thus permit short, predictable response times, even faster, deterministic data exchange with IO devices and a high immunity to interference from non-real-time data communication.

Read More...

Looking for "Distributed Controller" ?

Piece

Explore More Products

Our Blogs


Raise your Query

Hi! Simply click below and type your query.

Our experts will reply you very soon.

WhatsApp Us